PM880Specications
Overall
Channels
Single channel
Dimensions
• Size:9.4x5.5x1.5in(238x138x38mm)
• Weight,electronics:2.5lb(1.13kg)
• Weight,samplesystem:4lb(1.8kg)
Enclosure
Type4X,IP67
Electronics
Internal Battery
Rechargeable. PM880 batteries can be installed
orremovedinhazardousareas.Batteriesmustbe
recharged in non-hazardous areas only.
Battery Life
15to24hoursdependingontypeofprobe;batterylife
reducedwhenoperatingbelow32°F(0°C)
Battery Charger
• Switchableinput:115or230VAC,50/60Hz
• Requiresapproximatelythreehoursforfullbattery
recharge
Memory
FLASHmemory
Operating Temperature
14°to122°F(–10°to50°C)
To ensure maximum battery life, GE does not recommend
storing at temperatures exceeding 95°F (35°C) for longer
than one month.
Keypad
25-key,rubberized,tactilemembrane
Display
240x200pixel,graphicbacklitLCDdisplay
Printer/Terminal Output
Infrared communication port
Cables
Cabletypedependentonprobetype:MSeries,TFSeries,
orMoistureImageSeries.LEMO
®
-to-bayonet connector
Cable Length
• Standard:10ft(3m)
• Optional:ConsultGEforotherlengths
Hazardous Area Classication
Intrinsic-safetycertication:Baseefa(2001)Ltd. II1G
EExiaIICT3(–20°C≤T
a
≤+50°C)
Baseefa02ATEX0191;andCSACUSClassI,Division1,
GroupsA,B,C&D,Type6
European Compliance
ComplieswithEMCDirective89/336/EEC,ATEXDirective
94/9/EC
Operational
Site Parameter Programming
Menu-driven,graphic,operatorinterfaceuseskeypad
andsoft-functionkeys.Onlinehelpfunctions.Memory
storageforsavingsiteparameters.
Data Logging
Memorycapacitytologover100,000moisturedata
points.Programmablekeypadforlogunits,updatetimes,
and start and stop times.
Display Functions
Displaysmeasurementsandloggeddatainalphanumeric
or graphic format.
Display Units
• Moisture:DPtemperature,ppmv,ppmw,%RH,
lb/MMSCF,andothers
• Temperature:°F,°C,and°K
• Pressure:psig,bar,kPa(gauge),kg/cm
2
(gauge), and
others