Moisture Measurement
Compatibility
CompatiblewithallGEaluminumoxidemoistureprobes:
MSeries,TFSeries,andMoistureImageSeries.Each
probetyperequiresadierenttypeofI/Ocable.
Calibration
GEmoisturesensorsarecomputer-calibratedtoNational
InstituteofStandardsandTechnology(NIST)traceable
moisture concentrations.
Dew/Frost Point Temperature
Overall Calibration Range Capability
-166°Fto140°F(–110°Cto60°C)
Calibration Range Options
• Standard:68°Fto-112°F(20°Cto–80°C)withdatato
-166°F(–110°C)
• Ultralow:-58°Fto-166°F(–50°Cto–110°C)
• Extendedhigh:140°Fto-112°F(60°Cto–80°C)with
datato-166°F(–110°C)
Accuracy
• ±3.6°F(±2°C)from140°Fto-85°F(60°Cto–65°C)
• ±5.4°F(±3°C)from-85°Fto-166°F(–65°Cto–110°C)
Repeatability
• ±0.9°F(±0.5°C)from110°Fto-85°F(60°Cto–65°C)
• ±1.8°F(±1.0°C)from-86°Fto-166°F(–66°Cto–110°C)
Operating Pressure
5µofHgto5000psig(345bar)limitedbypressure
sensor—seepressuremeasurementspecications
Temperature Measurement
OptionalthermistoravailableforallGEmoistureprobes
Range
–22°Fto158°F(–30°Cto70°C)
Accuracy
±0.9°F(±0.5°C)at-22°F(–30°C)
Pressure Measurement
OptionalpressuresensoravailableforTFSeriesand
Moisture Image Series moisture probes
Ranges
• 30to300psig(3to21bar)
• 50to500psig(4to35bar)
• 100to1000psig(7to69bar)
• 300to3000psig(21to207bar)
• 500to5000psig(35to345bar)
Accuracy
±1%atfullscale
Proof Pressure
Threetimesspanofavailablerangeuptomaximum
7500psig(518bar)
Sample System
TheSS880Astandardsamplesystemcomprisesaninlet
needlevalve,abuilt-incoalescinglterandsamplecell
withabypassneedlevalveandventingtube,apressure
gauge(variousranges),andanoutletneedlevalvewith
ventingtube.
Wetted Parts
316SS
Operating Pressure
Congurationsavailablefor300,500,1000,2000,or
3000psig(21,35,69,207,or345bar),dependenton
pressure gauge)
Maximum Pressure Rating
• Standard:3000psig(207bar)
• Optional:5000psig(345bar)
Other Options
• Inletpressureregulator,0to500psig(1to345bar)
outlet
• Armoredowmeter,1.3to13SCFH
• 10-ft(3-m),exible,polytetrauoroethylene-lined,
braided–stainlesssteelhosewith1/4-inchtube
connections.Notrecommendedfordewpoint
temperaturesbelow–103°F(–75°C).

Other manuals for GE PM880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PM880 and is the answer not in the manual?

GE PM880 Specifications

General IconGeneral
BrandGE
ModelPM880
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals