Performance Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
lessthan or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent
MCL Challenge Concentration
Chlorine - 2.0 mg/L ± 10%
T&O - -
Particulate** - _>10,000 particles/mL
Influent
Average
1.96 mg/L
6,400,000#/mL
Effluent
Average Maximum
0.06mg/L 0.11mg/L
58,833#/mL 150,000#/mL
% Reduction
Average Minimum
96.77% 94.74%
99,14% 97,97%
Standard No. 53: Health Effects
Parameter Effluent
Turbidity
Casts
Asbestos
LeadatpH 65
LeadatpH 85
Mercuryat pH6.5
Mercuryat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dicNorobenzene
Atrazine
USEPA
MCL
0,5NTU
_>99,95%Reduction
_>99%Reduction
0.015mg/L
0.015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
0.003mg/L
Influent
Challenge Concentration
11+ 1NTU***
Minimum50,000L
107to 108fibers/L;> lOpm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
10.5NTU
118,750#/L
57MF/L
0.1567mg/L
0.1433mg/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087mg/L
Average
0.14NTU
<I#/L
0.996MF/L
<0.001mg/L
<0.001mg/L
0.000350mg/L
0.000325mg/L
0.00023mg/L
<0.00002mg/L
0.00337mg/L
0.00100mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
<0.0005mg/L
Maximum
0.28NTU
4#/L
<1 MF/L
<0.001mg/L
<0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002mg/L
0.011000mg/L
0.001000mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
<0.0005mg/L
% Reduction
Average Minimum
98.54% 97.20%
> 99.99% > 99.99%
99.60% 99.39%
99.36% 99.29%
99.30% 99.29%
94.70% 87.50%
93.20% 89.29%
99.34% 98.67%
99.00% 98.95%
98.32% 94.50%
93.44% 91.67%
96.51% 95.83%
98.78% 98.65%
99.78% 99.77%
94.22% 93,33%
Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20 °+_3°C)
** Measurement in Partictes/mt. Particles used were 0.5-1 microns
*** NTU=Nephetometric Turbidity units
Min.Required
Reduction
>50%
_>85%
Min. Required
Reduction
0.5NTU
_>99.95%
_>99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.04mg/L
0.075mg/L
0.003mg/L
Operating Specifications
$ Capacity: certified for up to 300 gallons (1135 I);up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
$ Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
$ Temperature: 33-100°F (0.6-38°C)
$ Flow rate: 0.5 gpm (1.9Ipm)
General Installation/Operation/Maintenance Requirements
$ Flush new cartridge at full flow for 3 minutes to purge out trapped air.
$ Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
$ Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
$ Thisdrinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
$ Donot use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
$ The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
$ Check for compliance with the state and local laws and regulations.
$ Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified bg NSFInternational against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cast and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY 40225
EPA EST. No. 070595-MN-001
47