9
SPECIFICATIONS (TECHNICAL DATA)
ELECTRICAL SPECIFICATIONS
Temperature Control (Position 5) 35-40
0
F
Defrost Control 10 hrs. @ 40 min.
Defrost Thermostat 55-25
0
F
Electrical Ratin
: 115V, AC 60 Hz. 3-6.Amp.
Maximum Current Leaka
e0.35 mA
Maximum Ground Path Resistance 0.5 Ohms
Ener
y Consumption 699 KWH/YEAR
NO LOAD PERFORMANCE
Control Position
Ambient Temperature 70
0
F90
0
F
Fresh Food,
0
F 34-40
0
F 35-40
0
F
Frozen Food,
0
F 2-8
0
F0-4
0
F
Percent Runnin
Time 38-48 45-61
REFRIGERATING SYSTEM
Minimum Compressor Capacity
Vacuum
21 in. H
Minimum Equalized Pressure
@ 70
0
F (21
0
C)
@ 90
0
F (32
0
C)
43 PSIG
50 PSIG
Refri
erant - R 134a 3.28 oz.
Compressor 778 BTU/H
INSTALLATION
Clearance must be provided at top, sides and rear of the refri
erator for air
circulation.
TOP 1 inch
SIDES 0.50 in.
REAR at condenser (metal cover
1- 1/4" when touchin
the wall)