COMPONENT SERVICABILITY
FRESH FOOD AND FREEZER DOORS
Doors are basic in construction consisting of steel external panels,
with foamed in insulation, plastic liner, shelves (narrow and wide),
with endcaps. Door gasket is attached to door panel screws through
a steel retainer strip which holds the gasket in place.
To replace door gasket:
1. Locate retainer strips and screws by pushing back gasket.
2. Remove screws.
3. Replace with new gasket using care not to roll gasket or misalign
and interfer with door closing operation.
(If gasket is leaking air, apply petroleum jelly to gasket to lubricate,
and soften if gasket is otherwise in good condition)
SHELVES
Shelves are mounted by attaching the shelf and endcap assembly to
the door liner in the approriate slots. The release on the endcaps is
accomplished by releasing a plastic tab on the inside of the left and
right endcap on each shelf (see below)
RETAINER STRIPS
GASKET
MIDDLE HINGE
BOTTOM
HINGE
HANDLE
LINER
DOOR
PANEL
FREEZER DOOR
DETAIL
FREEZER DOOR SHELVES
FRONT
SHELF
WIDE
END CAP
WIDE
END CAP
NARROW
FRONT SHELF
NARROW
PRESS TO
RELEASE