Service Mode
Test “t9” --- Agitate-2 Check (Infusor Wash)
• Press start to initiate test.
• Product will alternately rotate infusor CW then CCW for 1 minute.
Test “t10” --- Spin Check
Press start to initiate test.
• Pump will run until water frequency is under 26.0 KHz.
Tub will then slowly ramp up to maximum RPM (1000 RPM)
• RPM will be displayed.
Tub will spin at maximum RPM for 3 minutes.
After 3 minutes, tub will slowly decelerate to 0 RPM.
Note: 999 will be the maximum RPM displayed.