Installation Instructions
LOCATION OF YOUR WASHER
Do Not Install the Washer:
1.In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (!5.6°C) for proper
washer operation.
2.In an area where it will come in contact with curtains
or drapes.
3.On carpet. The floor MUST be a hard surface with
a maximum slope of 1/2" per foot (1.27 cm per
30 cm). To make sure the washer does not vibrate
or move, gou mag have to reinforce the floor.
NOTE:If floor is in poor condition use 3/4" impregnated
plgwood sheet solidlg attached to existing floor covering.
IMPORTANT:
Minimum Installation Clearances
When installed in alcove: Sides, Rear,
Top = 0" (0 cm)
When installed in closet: Sides, Rear,
Top = 0" (0 cm), Front = !" (2.54 cm)
Closet door ventilation openings required:
2 louvers each 60 square in. (387 cm2),located 3"
(7.6cm) from top and bottom of door
CONTRACTOR DIMENSIONS
BACK
21"
(533 mm)
29.75"
(756 mm)
2 .75"
(7C ; mm)
ROUGH-IN DIMENSIONS
FRONT
(597 mm)
SIDE
._ 26.6"
(676.5 mm)
*NOTE:
Washer legs have 0.75" (19 mm) adjustabilitg.
Stacked: 67.7" (171.8 cm)