Installation Information
WB28K10553 HIGH ALTITUDE KIT
For operation above 3,000 feet, order WB28KlOS53
Conversion Kit. This kit includes orifices for both LP
and Natural gas operation.
WB28K10554 DE-RATE KIT
(For a smell kitchen environment.}
De-rate conversion kit for use with model
ZDP304N (natural gas onlg). This kit includes
orifices to reduce surface burner output
to 40,800 BTU's.
MATERIALS PROVIDED
1/2" Pipe OvenRack
Anti-Tip Elbow Lubricant
Bracket,Brace
andScrews
Runners
(toprotect
flooring)
TOOLS REQUIRED
SaberSaw
MeasuringTape
Carpenter'sSquare
SafetyGlasses
Phillips#2 Screwdriver
Level
Drilland
AppropriateBits
AdjustableWrench
1/4" DriverorWrench
HandTruck
MATERIALS REQUIRED {not provided}
Joint PipeFittings Shut-0ffValve
Sealant
5-foot maximum length, 5/8" 0.D. CSA-approvedflexible
metal gas supply
(3-foot maximum length in Massachusetts only)
NOTE: Purchasenew flexible line; do not use
previously usedflexible gas line.