 49-5000355 Rev. 6
Auxiliary controls on your Zoneline
USING THE ZONELINE
MODE 5
Temperature Limiting
7HPSHUDWXUHOLPLWLQJLVDIHDWXUHWKDWUHGXFHVHQHUJ\
costs by limiting the lowest temperature that can be
obtained in cooling and the highest temperature that can
be obtained in heating.
Press MODE until a 5 appears in the first digit of the
display for Temperature Limiting. For cool mode,
the COOL/('OLJKWRQWKHPDLQFRQWUROZLOOEHOLW7R
change to heat mode, press MODE again and the HEAT
/('OLJKWRQWKHPDLQFRQWUROZLOOEHOLW
7RVHWWKHWHPSHUDWXUHOLPLWVSUHVVWKHRUSDG
7KHVHFRQGGLJLWRIWKHGLVSOD\ZLOOEHEHWZHHQDQG
GHSHQGLQJRQWKHOLPLW\RXZDQWWRVHW7KHEHORZFKDUW
shows the limits available. Press AUX SET to lock in
\RXUVHOHFWLRQDQGH[LWAUX SET mode, or press MODE
to continue setting other functions.
MODE 6
Use Wall Thermostat
Setting this mode to ON will allow the unit to operate
ZLWKD&ODVV5HPRWH&RQWURO:DOO7KHUPRVWDW
Press MODE until a 6 appears in the first digit of the
display for Class 2 mode.
7KHGHIDXOWVHWWLQJIRU0RGHLV2))
Press the + pad to turn the option ON “ ´IRU
³VWDQGDUGFRROKHDW´WKHUPRVWDWV3UHVVWKH+ pad
again to turn the option ON “ “ for “auto change
RYHU´WKHUPRVWDW<RXPD\SUHVVWKHSDGWRUHWXUQ
to the previous setting. Press AUX SET to lock in your
VHOHFWLRQDQGH[LWAUX SET mode, or press MODE to
continue setting other functions.
:KHQWKLVPRGHLVDFWLYHWKHGLVSOD\ZLOOVKRZ³8VH
:DOO7KHUPRVWDW´ZKHQDQ\NH\LVSUHVVHG
MODE 7
Duct Mode
7KLVVHWWLQJLVXVHGZKHQWKHXQLWLVLQVWDOOHGZLWKDGXFW
DGDSWHUNLW,IWKHXQLWLVGXFWHGWKH'XFW0RGHQHHGV
WREHVHWWR217KLVLQFUHDVHVWKHIDQVSHHGWRHQVXUH
proper circulation.
Press MODE until a 7 appears in the first digit of the
display. Press the + or - pad to change the second digit
to OFF “ or ON “ ´3UHVVAUX SET to lock in
\RXUVHOHFWLRQDQGH[LWAUX SET mode.
Press AUX SETWRORFNLQ\RXUVHOHFWLRQDQGH[LWAUX
SET mode or press MODE to continue setting other
functions.
7KHGHIDXOWVHWWLQJIRU0RGHLV2))
7KHGHIDXOWVHWWLQJIRU0RGHLVDVIROORZV
&RRO)WR)
+HDW)WR)
7HPSHUDWXUH/LPLWLQJ&RRO±/LPLW
2
7HPSHUDWXUH/LPLWLQJ+HDW±/LPLW
5
Duct Mode
OFF
Duct Mode ON
Class 2 OFF Class 2 ON
&RRO+HDW
Selectable
7KHUPRVWDWV
Class ON
(Auto Change Over
7KHUPRVWDWV
Temperature limits—Cool Temperature limits—Heat
 )WR)  )WR)  )WR)  )WR)
 )WR)  )WR)  )WR)  )WR)
 )WR)  )WR)  )WR)  )WR)
 )WR)  )WR)  )WR)  )WR)

Table of Contents

Other manuals for GE Zoneline AZ45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Zoneline AZ45 and is the answer not in the manual?

GE Zoneline AZ45 Specifications

General IconGeneral
BrandGE
ModelZoneline AZ45
CategoryAir Conditioner
LanguageEnglish

Related product manuals