EasyManua.ls Logo

GEA Grasso V 700 - User Manual

GEA Grasso V 700
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Reciprocating Compressors for industrial
refrigeration
GEA Grasso V
Installation and Maintenance instructions
0089288gbr_11

Table of Contents

Questions and Answers

Summary

SAFETY INSTRUCTIONS

CYLINDER NUMBERING, BOOSTER AND SINGLE-STAGE OPERATION

INSTALLATION AND PREPARATION FOR USE

INSTALLATION

Instructions for the proper installation of Grasso compressors.

PREPARATIONS FOR USE

Steps required before the compressor can be operated.

Initial oil charge

Procedures for filling the compressor with the correct oil.

PRESSURE SETTINGS

Configuration of pressure safety limit switches.

Starting and stopping procedures

Detailed steps for starting and stopping the compressor.

INSPECTION AND TROUBLE SHOOTING

Periodical inspection

Guidelines for regular inspections of the compressor.

TROUBLESHOOTING TABLE GRASSO RECIPROCATING COMPRESSORS

A table to help diagnose and remedy common faults.

MAINTENANCE

Post start-up maintenance

Maintenance tasks after the initial 100 operating hours.

APPENDIX; Product Information (PI)

GENERAL LIMITS OF OPERATION GRASSO V

Defines the maximum operational limits for the compressor.

STARTING UP OF TWO-STAGE COMPRESSORS

Procedures for starting two-stage compressor configurations.

Summary

SAFETY INSTRUCTIONS

CYLINDER NUMBERING, BOOSTER AND SINGLE-STAGE OPERATION

INSTALLATION AND PREPARATION FOR USE

INSTALLATION

Instructions for the proper installation of Grasso compressors.

PREPARATIONS FOR USE

Steps required before the compressor can be operated.

Initial oil charge

Procedures for filling the compressor with the correct oil.

PRESSURE SETTINGS

Configuration of pressure safety limit switches.

Starting and stopping procedures

Detailed steps for starting and stopping the compressor.

INSPECTION AND TROUBLE SHOOTING

Periodical inspection

Guidelines for regular inspections of the compressor.

TROUBLESHOOTING TABLE GRASSO RECIPROCATING COMPRESSORS

A table to help diagnose and remedy common faults.

MAINTENANCE

Post start-up maintenance

Maintenance tasks after the initial 100 operating hours.

APPENDIX; Product Information (PI)

GENERAL LIMITS OF OPERATION GRASSO V

Defines the maximum operational limits for the compressor.

STARTING UP OF TWO-STAGE COMPRESSORS

Procedures for starting two-stage compressor configurations.

GEA Grasso V 700 Specifications

General IconGeneral
TypeReciprocating
RefrigerantNH3, R22, R134a, R404A, R507
ApplicationIndustrial Refrigeration
Cooling MethodWater cooled
CapacityVaries depending on refrigerant and operating conditions
Motor PowerVaries by model and configuration
VoltageVaries depending on local standards
Frequency50 Hz / 60 Hz
WeightVaries by model and configuration
Cylinder ConfigurationV-type

Related product manuals