EasyManuals Logo

Gecko MSPA-MP METAPAC User Manual

Gecko MSPA-MP METAPAC
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
23MSPA-MP Metapacks Service Manual
Wrong Temperature Flow Chart
On MSPA-MP-NE packs, if system detects that temperature is not within
normal limits, wrong temperature will be displayed. Follow Troubleshooting
Flow Chart below to identify the problem:
Replace board if
problem persists.
Check if regulation
probe is properly connected.
Replace probe with
a spare and verify if
problem is solved.
If it is, replace
probe with spare.
Unplug probe connector
and clean pins on the
board (even a small coating
of film may cause a bad
connection).
Reconnect the probe.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko MSPA-MP METAPAC and is the answer not in the manual?

Gecko MSPA-MP METAPAC Specifications

General IconGeneral
BrandGecko
ModelMSPA-MP METAPAC
CategoryIndustrial Equipment
LanguageEnglish