54 MSPA-MP Metapacks Service Manual
Blower Does Not Work!
If blower is not working, carry out the following tests
to correct problem:
To increase the life of the relay, a "snubber" circuit is used on the blower relay.
With this type of circuit, if no blower is connected to an output and relays are open,
the voltmeter will continue to get a voltage reading of around 60 volts. This is normal.
It is important to measure voltage when the blower is connected to the pack.
Power must remain On.
1 Verify if "Blower" indicator
lights up on keypad display
when you press Blower key
(triangular icon will flash when
blower is in low speed).
2 Verify if blower low level pro-
gramming is set correctly.
3 If "Blower" indicator does not
appear on keypad display, then
replace keypad.
4 If "Blower" indicator still does
not appear on keypad display,
then replace board.
Blower
indicator