58 MSPA-MP Metapacks Service Manual
Spa Light Does Not Work!
If spa light is not working, carry out the following tests
to correct the problem:
It is important to measure voltage when light is connected to the pack.
Power must remain On.
1 The first step is to try replacing
the spa's light bulb.
4 If "Light" indicator appears, but
light still isn't working, make sure
light is at highest intensity setting
(indicator solid light, not flashing),
remove plastic cover and measure
voltage between opposite prongs
of connector P14 on the board.
If you get 12 VAC, replace light
socket.
5 If you aren't getting a voltage read-
ing, replace light fuse on the board.
6 If the problem persists, replace
board. (Refer to "How to Replace
the Board" section.)
Light fuse
2 If light still isn't working, verify if
"Light" indicator appears on
keypad display when you press
Light key.
"Light"
indicator
3 If "Light" indicator doesn't appear,
(verify low level programming first,
see Low Level Section) use a spare
keypad to verify if spa keypad is
defective.
If it is, replace keypad.
If not, replace board.