5MSPA-MP Metapacks Service Manual
If GFCI trips, follow Troubleshooting Flow Chart below to identify
the problem:
GFCI Flow Chart
Is GFCI
properly
connected?
If GFCI is
still tripping,
disconnect
the incoming
power line.
Is GFCI still
tripping?
Replace
GFCI.
Replace
board
if GFCI is
still tripping.
There is
a problem
with the
cable.
Call an
electrician.
Unplug
everything,
including
heater and light
cord wires.
Is GFCI
still tripping?
Replace
transformer.
Reconnect
one component
at a time
until GFCI
starts to trip.
Replace
defective
component.
Verify
Wiring Diagram
and reconnect it.
yes
yes no
no
yes no