29MSPA-MP Metapacks Service Manual
FLC Flow Chart
If FLC error condition occurs, follow Troubleshooting Flow Chart below to
identify problem (usually pressure switch problem - pump is off but water
pressure is detected):
Disconnect
pressure switch cable.
Does FLO error condition
occur when pump is on?
Adjust
pressure
switch.
Is it a new
installation
(less than
two years)?
Replace
pressure
switch cable.
Replace
pressure switch
if FLC error
condition
persists when
you start or
stop pump.
Replace
pressure switch.
Replace
board.
yes no
yes no
First ensure jumper position for circulation pump is set correctly
(see Jumper Section).