53MSPA-MP Metapacks Service Manual
Blower Flow Chart
If blower isn't working, follow this Troubleshooting Flow Chart
to identify the problem:
Does "Blower"
indicator appear
on keyboard display
when you press
Blower key?
Do you
read
120 VAC for
120 VAC blower
(or 240 VAC for 240 VAC)
at blower
output on
the board
(in high speed)?
Replace
blower
fuse.
It's possible
that blower
is not getting
enough air entry.
Create an opening
to allow more air
under spa skirt.
Replace board
if blower
still does
not start.
Replace
blower.
yes
yes no
no
Does
blower restart
after a few minutes
(to cool down
after being
shut off)?
yes no
Verify blower
low level
programming
(see Low Level Section).
Replace
keypad.
Replace
board.

Questions and Answers: