27MSPA-MP Metapacks Service Manual
FLO Error Condition
5 Ensure adequate water flow in the
heater and short two pressure switch
terminals with jumper cable.
6 If FLO error condition disappears,
perform the following steps:
If the installation is older than 2 years,
replace the pressure switch and re-
calibrate it.
If installation is recent, try readjust-
ing the pressure switch. If this is not
possible, replace switch.
(Refer to "How to Adjust the
Pressure Switch" section of this
manual.)
7 If FLO error condition persists, the
problem may be either with switch
cable or board.
Remove plastic cover and replace
cable.
8 Replace board if FLO error condition
still persists. (Refer to "How to Replace
the Board" section.)