EasyManuals Logo

Gecko MSPA-MP METAPAC User Manual

Gecko MSPA-MP METAPAC
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
32 MSPA-MP Metapacks Service Manual
Prr Error Condition
The Prr error condition indicates a problem with regulation sensor.
The system is constantly verifying if temperature probe reading is
within normal limits.
Note that water temperature must be over 35°F in order to carry out the following steps.
Pressing any key after each step resets system. Power can remain On.
1 Verify if regulation probe (sensor
located in spa) is properly
connected.
3 Reconnect probe.
If Prr error condition still persists,
replace probe with a spare and
place probe head directly in spa
water.
If problem is solved, replace
probe.
4 Replace board if problem persists.
2 Disconnect probe connector
and clean probe connector pins.
Even a small coating of film may
cause a bad connection.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko MSPA-MP METAPAC and is the answer not in the manual?

Gecko MSPA-MP METAPAC Specifications

General IconGeneral
BrandGecko
ModelMSPA-MP METAPAC
CategoryIndustrial Equipment
LanguageEnglish