35MSPA-MP Metapacks Service Manual
HL Error Condition
If weather is very hot:
1 Remove spa cover (even during the night). Start blower if spa is equipped
with one. Wait until spa cools down (add cold water if necessary).
If hot weather is not a factor:
2 Lower set point below current
water temperature.
The "Heater" indicator should
disappear from keypad display.
If digital thermometer water temperature reading is at 112°F or higher
and keypad display indicates correct temperature, carry out the following
tests:
3 Remove the plastic cover. With
a voltmeter, read the voltage
between the two heater wires
on the board.
4 If you do not read 240 VAC, pump
may be overheating water during
filter cycle.
Enter Programming mode and
shorten filter cycle duration.
5 If you do read 240 VAC, replace
board. (Refer to "How to Replace
the Board" section of this manual.)