50 MSPA-MP Metapacks Service Manual
Pump 2 Does Not Work!
If Pump 2 is not working, carry out the following tests to correct the
problem:
To increase the life of the relay, we use a "snubber" circuit on the pump relay.
With this type of circuit, if no pump is connected to an output and relays are open,
the voltmeter will get a reading of around 60 volts. This is normal.
It is important to measure voltage when pump is connected to the pack.
Power must remain On.
2 Verify if "Pump 2" indicator appears
on keypad display when you press
Pump 2 key.
If "Pump 2" indicator does not ap-
pear, check low level programming
first (see Low Level Section).
4 If "Pump 2" indicator appears on
the display when you press Pump 2
key, verify if Pump 2 works in any
speed.
1 Check for any error condition on
keypad display. If there are, refer
to specific section indicated by the
error condition.
"Pump 2" indicator
3 If "Pump 2" indicator does not
appear, use a spare keypad to
verify if spa keypad is defective.
If it is, replace keypad.
If not, replace board.