43
RS-232 SERIAL COMMANDS
OUT Command
The OUT command sets the output resolution.
Syntax:
OUT param1
Parameters:
param1 Resolution
Resolution Meaning
native Native resolution of display
vga 640 x 480
svga 800 x 600
xga 1024 x 768
sxga 1280 x 1024
uxga 1600 x 1200
480i 640 x 480i / 720 x 480i
480p 640 x 480p / 720 x 480p
720p60 1280 x 720p
1080i60 1920 x 1080i @ 60 Hz
1080p60 1920 x 1080p @ 60 Hz
576i 720 x 576i
576p 720 x 576p
720p50 1280 x 720p @ 50 Hz
1080i50 1920 x 1080i @ 50 Hz
1080p50 1920 x 1080p @ 50 Hz
wxga 1280 x 768
wsxga 1680 x 1050
wuxga 1920 x 1200
1080p24 1920 x 1080p @ 24 Hz
2k60 2048 x 1080 @ 60 Hz
Notes:
Use ? for param1 to retrieve the current value.