4-46
03-18
03-17
RUN command
03-11=14
Hz
T
ON
OFF
RUN STOP
03- 19
Relay Output Status type
Range
0
:A (Normally open)
1
:B (Normally close)
03- 20
Brake Transistor ON Level
Range
230V:240.0~400.0VDC
400V:500.0~800.0VDC
03- 21
Brake Transistor OFF Level
Range
230V:240.0~400.0VDC
400V:500.0~800.0VDC
When DC bus voltage >03-20 Excess voltage will be applied to the external brake resistor.
When DC bus voltage <= 03-21 Braking transistor will be switched off.
Do not set 03-21 > 03-20, or display will show Err2, which means parameter setting error.