Questions and Answers

  • B
    Bruce ContrerasSep 18, 2025
    What to do if Gefran Inverter shows Rope change [ROPC]?
    • C
      codyramosSep 18, 2025
      The 'Rope change' alarm on your Gefran Inverter may occur in two conditions: - The drive continues to run, but the rope usage threshold set in parameter has been reached. - The drive finishes the current travel and then locks because parameter has reached 0. Replace the ropes. By switching the drive off and back on you can run a single travel to bring the car to a better position for the procedure. After you have changed the ropes, reset the direction change counter to eliminate the lock condition.
  • R
    Robin BanksAug 25, 2025
    What to do if Gefran Inverter displays Overcurrent [OC]?
    • M
      Michael BurgessAug 25, 2025
      If your Gefran Inverter is showing an overcurrent alarm, it means the instantaneous overcurrent protection has been triggered. This could be due to incorrect settings of the current regulator parameters or a short circuit between phases or a ground fault on the drive output. Check the current regulator parameters and inspect the wiring to the motor.
  • D
    Donna WilsonAug 26, 2025
    What causes Heatsink OT [HOT] alarm on Gefran Inverter?
    • G
      glendatoddAug 26, 2025
      The 'Heatsink OT' alarm on your Gefran Inverter indicates that the heatsink temperature is too high. This could be due to several reasons: - The cooling fan may not be working correctly. - The heatsinks might be clogged. - The openings for the cabinet cooling air could be blocked. Verify the correct operation of the cooling fan, check for any blockages in the heatsinks, and ensure that the cabinet cooling air openings are not obstructed.
  • K
    Kimberly Schmidt DDSAug 27, 2025
    What to do if Gefran Inverter shows Undervoltage [UV]?
    • M
      Michael DuncanAug 27, 2025
      If your Gefran Inverter is displaying an undervoltage alarm, it signifies that the voltage arriving at the drive power section is too low compared to the minimum threshold related to the Mains voltage parameter setting. This can occur if the mains voltage is too low or due to overextended voltage drops. Poor cable connections, such as loose contactor terminals, inductance, or filters, can also cause this issue. You should check the connections and mains voltage.
  • M
    Mr. Chad JonesSep 22, 2025
    What to do if Gefran Inverter displays Plc cfg error [PLCE]?
    • C
      Christopher RogersSep 22, 2025
      The 'Plc cfg error' alarm on your Gefran Inverter can occur during loading of the MDPLC application. The Mdplc application present on the drive is not run. Remove the MDPLC application or download a correct MDPLC application.
  • K
    Kylie BartonSep 23, 2025
    What does Key failed [KEY] mean on Gefran Inverter?
    • D
      Douglas MartinezSep 23, 2025
      The 'Key failed' alarm on your Gefran Inverter can occur at drive power-on if the wrong enabling key is entered for a given firmware function. Contact Gefran to request the key to enable the desired firmware function.
  • L
    Leah Nichols MDSep 9, 2025
    How to fix Overspeed [OS] alarm on Gefran Inverter?
    • R
      reginald97Sep 9, 2025
      A 'Motor overspeed' alarm on a Gefran Inverter indicates that the motor speed exceeds the limits set in the parameter. To resolve this, limit the speed reference and check that the motor is not driven in overspeed during rotation.
  • J
    Jason PerezSep 12, 2025
    What does External fault [EF] mean on Gefran Inverter?
    • J
      johnmendozaSep 12, 2025
      An 'External fault' alarm on your Gefran Inverter indicates that a digital input programmed as an external alarm does not have the +24V voltage available on the terminal. To resolve this, check that the terminal screws are tight.
  • P
    Paul WalshSep 3, 2025
    How to troubleshoot Bres overload [BOL] on Gefran Inverter?
    • J
      jenniferriveraSep 3, 2025
      A 'Braking resistor overload' alarm on a Gefran Inverter means that the current absorbed by the resistor is greater than its rated current. Check the size and condition of the braking resistor.
  • E
    edwardsjonathanSep 1, 2025
    How to fix Drive overload [DOL] on Gefran Inverter?
    • D
      Damon MillerSep 1, 2025
      A 'Drive overload' alarm on a Gefran Inverter means that the inverter output current has exceeded the allowed overload value, or the overload cycle has exceeded the allowed values. Check that the load and accelerations are not excessive, and ensure that the overload cycle is within the allowed limits.

Summary

Safety Precautions

General Warnings and Hazards

Details general warnings, electrical shock, and fire/explosion hazards.

Electrical Installation

ADL300 Typical Installation and Main Sections

Overview of the ADL300's power and regulation sections and their connections.

Power Section Wiring Details

Covers shielding connection and EMC guidelines for the power section wiring.

Motor and Braking Resistor Connections

Shows wiring diagrams for motor connections and optional braking resistors.

Feedback Connection

Describes feedback connections for ADL300B series and shielding recommendations.

Encoder Feedback Connections

Illustrates connections for SinCos, SE, and EnDat encoders.

EnDat Encoder and Digital Encoder Connections

Shows connections for EnDat Full Digital and digital encoders.

Digital and Sinusoidal Encoder Connections

Details digital encoder connections and Sinusoidal SinCos Encoder with repetition.

Keypad Operation

Commissioning

Motor and Encoder Setup

Details motor data setup, including rated voltage, current, speed, and pole pairs.

Encoder Data Setup and Autotuning

Explains encoder setup, direction, pulses, and the autotuning/autophasing procedures.

Brake Sequence and Emergency Operation

Explains brake timing sequences and emergency power supply modes.

Fine Adjustment

Alarms and Troubleshooting

Alarm Codes and Descriptions

Lists and explains various alarm codes displayed by the drive.

Speed Feedback Loss Alarms

Details causes and solutions for speed feedback loss alarms based on encoder type.