4-50
Analog Output (AO) function selection.
0
:Output frequency
1
:Frequency Setting
2
:Output voltage
3
:DC Bus Voltage
Example: Set 04-11 required according to the following table.
0
10V
Xmax
A
Xmax( 04-11)
Xmax / 2
5 V
0 ~ 1000
%
0 ~ 100
%
0
: Positive
1
: Negative
0
: Positive
1
: Negative
Select the Analog output type for the multifunction analog output on terminal (TM2)
as required by parameter 04-11. Output format is 0-10V dc.
The output voltage level can be scaled and modified by parameters 04-12 to 04-15 If
necessary.
The modification format will be same as the examples shown previously for Analog Voltage
Input (AVI) parameters 4-02 to 4-05.
Note: the max output voltage is 10V due to the hardware of the circuit.
Use external devices that require a maximum of 10V dc signal.
Potentiometer / frequency curve gain setting
Range
0 ~ 1000
%
Potentiometer / frequency curve bias (offset) setting
Range
0 ~ 100
%
Potentiometer / frequency curve bias (offset) signe selection
Range
0
: Positive
1
: Negative
Potentiometer / frequency slope of the curve selection
Range
0
: Positive
1
: Negative
Setting of frequency (main / alternative) by potentiometer on integrated keypad.
0
Output frequency
upper frequency limit
1
Frequency Setting
upper frequency limit
2
Output voltage
Motor Rated Voltage
3
DC Bus Voltage
:
4
Output current
2 times rated current