131
MAINTENANCE
If the uid level can not be checked by
uid level lines.
Remove the caps (2) and look into the fluid
supply holes to check the fluid level. If the
uid is below the sleeve (3), be sure to add
distilled water up to the bottom edge of the
sleeve (3).
Proper amount ...... (A)
The uid reaches up to the bottom edge
of the sleeve (3), so the surface tension
causes the fluid to swell and the plate
appears distorted.
Level too low ......... (B)
The uid does not reach up to the bottom
edge of the sleeve (3), so the plate appears
laminar, not distorted.
4. Also check the terminals for looseness
and dirt.
Replenishing
When adding distilled water, do so before
starting operations in order to prevent
freezing.
1. Remove the bolts (a) and open the radiator
(b).
Every 50 Hours
2. Remove the indicator (1) and caps (2), and
add distilled water up to the upper level.
3. Tighten the indicator (1), which then turns
blue.
4. Clean the caps exhaust hole, then tighten
the caps (2) securely.