EasyManuals Logo

Gehl CTL85 User Manual

Gehl CTL85
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
MAINTENANCE
132
Every 50 Hours
Draining the Fuel Tank
WARNING
Do not smoke or permit open flames
while handling fuel or working on the
fuel system.
Stop the engine in a well-ventilated
place and allow it to cool before
performing maintenance.
Clean up spilled fuel immediately.
Do this before operating the machine.
1. Remove the fuel ller cap (2).
2. Place a pan under the drain plug (3).
3. Remove the cover (4).
4. Remove the drain plug (3) and drain the
water and sediment from the bottom of
the tank.
5. Tighten the drain plug (3).
6. While watching the fuel gauge (1), add
fuel.
7. Tighten the fuel ller cap (2) and lock it
with the key.
Bleeding the air from the fuel system
Refer to page 159, “Bleeding the Air from the
Fuel System.
Note: Air in the fuel system can make it
difficult to start the engine and cause engine
problems. Also bleed the air when the fuel
tank is emptied.
1
T7G0071
3
2
4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl CTL85 and is the answer not in the manual?

Gehl CTL85 Specifications

General IconGeneral
BrandGehl
ModelCTL85
CategoryTractor
LanguageEnglish

Related product manuals