18
KEYPAD FUNCTIONS
Activate Telephone Test? (Telephone Test programmed? qYES qNO). Sends a
communicator test to the central station. A communication failure will be
indicated at the keypad by a system trouble “E03-FAIL TO COMM” display.
Repeat the test to attempt to correct a communication failure, as any successful
communication will clear this display.
Delay Arming 1-4 hours. (Not for UL-listed systems.) Your system may be set to
arm automatically after a delay period of 1 to 4 hours.
To Delay Arm the system:
With the function “TO ARM IN 1-4 HRS“ displayed in the window, enter the desired
Delay Arming time in hours (1,2,3,or 4), followed by J.
At the end of this 1 - 4 hour Delay Arming period, the siren will sound a 2-second
warning and the keypad will begin a 15-minute arming countdown with the sounder
pulsing. The sounder may be silenced at this time by pressing C, but it will turn
back on with a steady warning tone 1 minute prior to arming, at which time the
building must be exited.
The same steps can be used to delay a scheduled Auto Arming, if your system has
been programmed as such.
ACTIVATE
DIALER TEST Y/N
TO ARM IN 1-4 HRS
PRESS 1-4 /N