&$6&$'(2)6(9(5$/7+5 
&211(&7,21%(7:((15(*8/$7256
Be sure to observe the polarity of the connection of
the communication bus:
- connection between THR 10-100:
connect terminals DB with each other as well
as the MB terminals of terminal boxes 4 (ob-
serve the polarity),
- connection between THR 10-100 and terminal
box ZH 46:
terminal 8 of terminal box(es) ZH 46 with termi-
nal DB of terminal box 4 of the THR 10-100,
terminal 9 of box(es) ZH 46 with terminal MB of
terminal box 4 of the THR 10-100.
5(*8/$7253$5$0(7(56(77,1*
DB DB
8
9
8
9
MB MB
ZH 46 ZH 46
RVA 47
/
1
/
1
DB
MB
M
DB
MB
M
RVA 46RVA 46
Rear view of the RVA
control panel
RVA 47
/
1
/
1
RVA 46RVA 46
To other
ZH 46
control boxes
To other
THR 10-100
(4 maximum)
7HUPLQDOER[
7HUPLQDOER[
/
1
/
1
/
1
/
1
/
1
/
1
/
1
/
1
)LJ
Unit address
Segment address
Segment 0 = Heat producting unit RVA 47
Segment 1 = Heat distribution unit RVA 46
3&
'&
= Heat producer RVA 47
= Heat distributor RVA 46
7+5
RVA 47 RVA 46 RVA 46
R
V
A
4
6
R
V
A
4
6
=+
=+
0


1

7+57+57+5
(maître)
RVA 47 RVA 46 RVA 46RVA 47 RVA 46 RVA 46RVA 47 RVA 46 RVA 46
3
&
'
&
Unit address
Segment address







)LJ
See fig. 67 for complete parame-
ter setting