8.2.4 CLEANING THE CONDENSER
Carry out this operation every 30 days.
APPLIANCE STATUS:
- I/O main switch in position “O” (OFF);
- power supply plug disconnected from the mains.
AUTHORIZED PERSONNEL
Appliance operator.
METHOD
To ensure that the appliance works properly and efficiently, the air condenser (ref. 1 fig. 9) must be kept clean so that the
air can circulate freely. This operation should be carried out every 30 days. Remove the control panel by loosening the
screws (ref. 2 and 3 fig. 9). Clean with a non-metal brush to remove all the dust and fluff from the fins. It is advisable to
use a vacuum cleaner so that dust does not float in the air. If there are greasy deposits, eliminate with a brush soaked in
alcohol. DO NOT SCRAPE THE SURFACES WITH POINTED OR ABRASIVE OBJECTS.
Fig. 9
The condenser has sharp edges. When carrying out the operations mentioned above, wear safety
gloves, goggles and face masks.
Do not use direct water jets to clean the appliance.