EasyManua.ls Logo

Gemtech GTP211D - Troubleshooting and Support; Troubleshooting Common Issues

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GTP110D / GTP211D
15
69-2425EFS—03
ENGLISH
Screen is blank. • Ensure two fresh AAA alkaline batteries are correctly installed.
Temperature settings cannot
be changed.
• The System switch is off.
• You are setting the temperature outside its allowable range:
• Heat: 40°F to 90°F (4.5°C to 32°C)
• Cool: 50°F to 99°F (10°C to 37°C)
Cool On or Heat On is
flashing.
• The compressor protection delay is underway. Wait for the delay to end
(maximum of 5 minutes).
HI appears on the screen. • The ambient (measured) temperature is above 122°F (50°C).
LO appears on the screen. • The ambient (measured) temperature is below 32°F (0°C).
E1 appears on the screen. • The temperature sensor circuit is opened. Replace the thermostat.
E2 appears on the screen. • The temperature sensor circuit is shorted. Replace the thermostat.
In case of difficulty

Related product manuals