WARNING: THIS UNIT IS NOT PROVIDED WITH A GFDI DEVICE. Consult Article 690 of the National Electrical Code (or the standards in force at the installation location)
to determine whether a GFDI is necessary for your installation.
Use only 10-30 AWG (5.0 mm
2
max) copper conductors suitable for a minimum of 60 degrees C. If operation at high power or at high ambient temperatures is expected,
wire with a higher temperature rating may be necessary. Recommended terminal block tightening torque: 7 in-lbs, 0.79 Nm.
WARNING: THIS UNIT IS NOT PROVIDED WITH DISCONNECT DEVICES. Consult Article 690 of the National Electrical Code (or the standards in force at the installation
location) to determine whether disconnect devices are necessary for your installation.
LITHIUM WARNING: Use caution when working with lithium systems. Genasun Li controllers use the CC/CV charging prole indicated on the controller. CHECK the
specications of the battery pack to ensure that the CV voltage is correct. Further check that the power supplied by the solar array and Genasun controller is within the
battery specied design limits.
LITHIUM BMS WARNING: Genasun recommends using a lithium battery with a Battery Management System (BMS) capable of disconnecting the solar charge controller in
the event that any cell in the pack is outside of its rated temperature, current, or voltage range. Failure to do so may result in property damage, injury or death. Genasun
highly recommends the use of a BMS with cell balancing. Cell balancing is mandatory for lithium iron phosphate.
Inspection & Maintenance
Inspect the controller at least once per year to ensure proper performance.
Check for animal or insect damage.
Inspect for corrosion / water damage.
Product Certifications
1
Safety
Conforms to:
UL STD 1741
Certied to:
CSA STD C22.2#107.1
HazLoc (C1D2)
Conforms to:
UL STD 121201
Certied to:
CSA STD C22.2#213
EMC
Conforms to:
EN 61000-6-3:2007+A1:2011
EN 61000-6-2:2005
AS/NZS 61000-6-3:2012
EMC
Conforms to:
FCC (CFR Title 47) Part 15 Radio frequency
Devices, Subpart B - Unintentional Radiators.
Tested for compliance.
Restriction of Hazardous Substances
Conforms to:
EN 50581:2012
(1) The GVB-8-PCB models are ETL Recognized Components for safety (UL1741).
Inspect the security of all connections.
Ensure the solar array does not exceed the maximum input voltage.
Repair and clean as necessary.