tening position is dependent upon the posi-
tion of the subwoofer.
Two phase matching switches in the
crossover allow compensation for incorrect
phasealignment.Foursettingsareprovided
between0°and-270°.
Coarse phase correction
method
• Conguretheprocessorsothatthemain
speakers(L,C,R)aresetto“small”and
check the main speaker/subwoofer
crossover frequency setting on your
processor. This frequency may be
variableorxed:consulttheoperating
manual of your processor.
• Connectanaudiosignal
generator to one of the input channels
used in the system.
• Setthesignalgeneratortothesame
frequency as the subwoofer crossover
frequency on your decoder. If a signal
generator is not available, you can use an
audio test recording with a suitable range
of test frequencies.
• Togglethe-180°phase
switch(#4)"ON"and"OFF"
and set it to the position
which gives the lowest sound
level at the listening position.
• Nexttogglethe-90°phase
switch(#3)"ON"and"OFF",
and again set it to the
position which gives the
lowest sound level.
• Finally,setthe-180°phase
switch to the opposite setting.
After the phase setting has been completed,
returnthespeakercongurationontheproc-
essor to its’ original settings.
Using multiple subwoofers
The5041Aisequippedwitha“LINKOUT”
connector to provide an easy way of cou-
pling two or more subwoofers together in
high SPL applications. Connect an XLR
cablefromthe“LINKOUT”connectorofthe
master subwoofer to which the decoder is
connected,tothe"XLRIN”inputconnec-
tor of the other, slave subwoofer. When
two subwoofers connected in this way
are positioned close to one another, bass
levelincreasesby6dB.Threesubwoofers
givea bassSPLincrease of9,5dB and
foursubwoofersprovidea12dBincrease
compared to a single subwoofer. Adjust the
sensitivity control of all subwoofers in the
grouptomatchtheSPLlevelofthemain
loudspeaker system. Note that the sensitiv-
ity setting must be the same on all subwoof-
ers.
Autostart and Remote
ControlFunction
The 5041A is equipped with an“AUTO-
START” function, which automatically
turnstheamplierto“STANDBY”modeif
an input signal has not been detected for
approximately30minutes,andbackto“ON”
mode when the signal returns. The function
canbedeactivatedbyturningthe“AUTO-
START”dipswitchto“OFF”.Atwo-colour
LEDon theamplier panel indicatesthe
amplierstatus:greenfor“ON”andyellow
for“STANDBY”.
Theampliermodecanalsobeswitched
by a 12Vtrigger type remote control unit
connected to the respective inputs on the
amplier(see"SubwooferCabling").Switch
the“REMOTECONTROLdipswitchto“ON”
to activate this function. Remote control over-
ridesthe“AUTOSTART”function.
AutomaticProtectionCircuits
The 5041A is equipped with protection cir-
cuits against bass driver thermal overload
and amplifier overheating. The protection
system resets automatically so that the user
only has to turn the input level down to ensure
that it does not reactivate.
Safety considerations
The Genelec 5041A complies with interna-
tional safety standards. However, to ensure
safe operation and maintain the equipment in
safe operating condition the following warn-
ings and cautions must be observed.
• Servicingandadjustmentmustonlybe
performedbyqualiedservicepersonnel.
• Openingtheamplierisstrictly
prohibitedexceptbyqualiedservice
personnel.
• Donotexposethesubwooferoramplier
towaterormoisture.Donotplaceany
objectslledwithliquid,suchasvaseson
or near them.
• Alwaysuseamainspowercableand
connectionwithprotectiveearth.Failing
to do this may lead to personal injury.
• Notethattheamplierisnotcompletely
disconnected from the AC mains service
unless the mains cable is removed from
theamplierorthemainsoutlet.
Warning!
This equipment is capable of delivering sound
pressurelevels inexcessof85 dB,which
may cause permanent hearing damage.
Maintenance
There are no user serviceable parts inside
the amplifier or subwoofer enclosure. Any
maintenance of the unit must only be per-
formedbyqualiedservicepersonnel.
Guarantee
This product is supplied with two year guaran-
tee against manufacturing faults or defects that
might alter the performance of the unit. Refer
to supplier for full sales and guarantee terms.

Other manuals for Genelec 5041A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genelec 5041A and is the answer not in the manual?

Genelec 5041A Specifications

General IconGeneral
BrandGenelec
Model5041A
CategorySubwoofer
LanguageEnglish

Related product manuals