3.13 SERVICE SCHEDULE
ATTENTION: It is recommended that all service work
be performed by the nearest Generac Authorized Service Dealer.
SYSTEM/COMPONENT PROCEDURE FREQUENCY
X = Action Inspect Change Clean D = Daily W = Weekly
R = Replace/Adjust as Needed M = Monthly Y = Yearly
* = To Be Completed by a H = Hours
Generac Authorized
Service Dealer.
FUEL
Fuel level X AFTER 25-H BREAK-IN,
D / BEFORE USE
Fuel lines and connections* X AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Fuel Filter* X EVERY 250 H / 6 M
LUBRICATION
Oil level X EVERY 8 H / D
Oil X AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Oil Filter X AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Oil line leakage* X EVERY 100 H
COOLING
Engine cooling system* X AFTER 25-H BREAK-IN,
EVERY 100 H / M
Coolant level X AFTER 25-H BREAK-IN,
D / BEFORE USE
Coolant* X EVERY 500 H / Y
Enclosure louvers X X EVERY 250 H / 6 M
EXHAUST
Exhaust system X EVERY 100 H / M
Retorque Exhaust Manifold* X EVERY 750 H
Clean out Muffler/Spark Arrestor X EVERY 150 H/Y
BATTERY
Electrolyte fluid level X AFTER 25-H BREAK-IN, W
Charge and condition X R X W, EVERY 250 H / 6 M
FAN/ALTERNATOR BELTS
Tension and condition* X R EVERY 750 H
ENGINE
Retorque cylinder head* X EVERY 750 H
Retorque intake manifold* X EVERY 750 H
Starter motor* X EVERY 750 H
Air filter X R EVERY 500 H
Compression* X EVERY 750 H
Valve clearance* X R EVERY 750 H
Governor* X R EVERY 750 H
Safety devices* X R EVERY 750 H
Injection system* X R EVERY 750 H
GENERAL
Overall condition X X AFTER 25-H BREAK-IN, W
Exercise system W
COMPLETE TUNE-UP* XXX Y
16 Generac
®
Power Systems, Inc.
Section 3 – Maintenance
QUIETPACT™ 75D Recreational Vehicle Generator

Table of Contents