Owner's Manual
XG Series 6,500-8,000 W
att P
or
table Generator
MODELS: 005796-0 (XG6500), 005797-0 (XG7000),
005798-0 (XG7000E), 005800-0 (XG8000),
005747-0 (XG8000E)
Actoolsupply.com
Actoolsupply.com

Table of Contents

Questions and Answers

  • R
    Robert QuinnAug 17, 2025
    What to do if my Generac Power Systems Portable Generator is running but has no AC output?
    • R
      robinsongailAug 17, 2025
      If your Generac Power Systems Portable Generator engine is running but there's no AC output, check the following: 1. The circuit breaker might be open. Reset the circuit breaker. 2. There may be a poor connection or defective cord set. Check and repair the connection or cord set. 3. The connected device could be faulty. Connect another device that is in good condition. 4. GFCI trips the 20 Amp outlet. Repair the "short" and reset the GFCI. If these steps don't resolve the issue, there may be a fault in the generator, and you should contact an Authorized Service Facility.
  • S
    Stephanie MasonAug 20, 2025
    Why does my Generac Power Systems Portable Generator engine shut down while running?
    • C
      cwyattAug 21, 2025
      If your Generac Power Systems Portable Generator engine shuts down during operation, it could be due to: * Being out of gasoline. Fill the fuel tank. * A low oil level. Fill the crankcase to the proper level. If neither of these is the cause, there may be a fault in the engine, and you should contact an Authorized Service Facility.
  • N
    nancy79Aug 25, 2025
    What to do if my Generac Power Systems Portable Generator runs fine but bogs down with a load?
    • T
      Todd CantuAug 26, 2025
      If your Generac Power Systems Portable Generator runs well but bogs down when loads are connected, consider these possibilities: * There might be a short circuit in a connected load. Disconnect the shorted electrical load. * The generator could be overloaded. Consult the section on how not to overload the generator. For issues related to engine speed or a shorted generator circuit, contact an Authorized Service Facility.
  • W
    wilkinskarenAug 28, 2025
    Why does my Generac Power Systems Portable Generator lack power?
    • K
      Kristopher KelleyAug 28, 2025
      If your Generac Power Systems Portable Generator engine lacks power, consider the following: * The load might be too high. Refer to the section on avoiding generator overload. * The air filter might be dirty. Replace the air filter. If these steps don't improve the power, the engine may need servicing, and you should contact an Authorized Service Facility.
  • R
    richardhamptonSep 1, 2025
    How to fix a Generac Power Systems 005796-0 (XG6500) Portable Generator that will not crank?
    • S
      Stephen GarciaSep 1, 2025
      If your Generac Power Systems Portable Generator will not crank, it could be due to: * A weak or dead battery. Recharge or replace the battery. * If the battery is not the issue, you can start the engine manually using the recoil starter.
  • P
    Pamela WoodsSep 5, 2025
    Why does my Generac Power Systems Portable Generator engine hunt or falter?
    • E
      evansalanSep 5, 2025
      If your Generac Power Systems Portable Generator engine "hunts" or falters: * The choke might be opened too soon. Move the choke to the halfway position until the engine runs smoothly. If the problem persists, the carburetor may be running too rich or too lean, and you should contact an Authorized Service Facility.
  • A
    Alyssa VillegasSep 8, 2025
    What causes no battery charger DC output on a Generac Power Systems 005796-0 (XG6500)?
    • C
      Christine MuellerSep 8, 2025
      If there is no Battery Charger DC output from your Generac Power Systems Portable Generator, check the following: 1. Battery posts may be corroded. Clean the battery posts. 2. The battery cable may be bad. Replace the cable. 3. The battery may be defective. Check the battery condition; replace if defective. 4. The Battery Charger in-line fuse (1.5A) may have melted open. Replace the fuse with an identical 1.5A replacement fuse only (located inside the control panel). If these steps don't resolve the issue, the receptacle may be bad, and you should contact an Authorized Service Facility.
  • J
    Jason ArroyoNov 12, 2025
    Why won't my Generac Power Systems Portable Generator start, or why does it run rough?
    • A
      Andre SullivanNov 12, 2025
      If your Generac Power Systems Portable Generator engine won't start or runs rough, there are several possible causes: * The fuel shut-off may be OFF. Turn the fuel shut-off ON. * The air cleaner might be dirty. Clean or replace the air cleaner. * The generator may be out of gasoline. Fill the fuel tank. * The gasoline may be stale. Drain the fuel tank and fill with fresh fuel. * The spark plug wire may not be connected to the spark plug. Connect the wire to the spark plug. * The spark plug may be bad. Replace the spark plug. * There might be water in the gasoline. Drain the fuel tank and fill with fresh fuel. * The engine might be over-choking. Put the choke knob to the No Choke position. * The oil level could be low. Fill the crankcase to the proper level. For other po...

Summary

Introduction

Read this Manual Thoroughly

Operator responsibility to read and understand all instructions before use.

Safety Warnings and Symbols

Explains DANGER, WARNING, CAUTION blocks and associated safety symbols.

General Hazards Overview

Lists general safety precautions for generator operation and maintenance.

Safety Rules

Specific Hazards (Exhaust, Electrical, Fire)

Details safety precautions for exhaust fumes, electrical shock, and fire risks.

Standards and Warnings

Lists relevant industry standards and California Proposition 65 warnings.

General Information

Unpacking and Assembly

Instructions for unpacking, checking accessories, and assembling the generator.

Operation

Generator Controls and Features

Familiarizes the user with the generator's controls, features, and components.

Battery, Hourmeter, and Receptacles

Covers battery connection, hourmeter, receptacles, and cord sets.

Grounding, Usage, and Starting

Explains grounding, general usage, and starting procedures.

Load Connection and Overload Prevention

Guidance on connecting loads, preventing overload, and wattage reference.

Pre-Start Checks and Procedures

Guidance on pre-start checks, adding fluids, and engine starting methods.

Maintenance

Maintenance Schedule and Specifications

Outlines routine maintenance tasks, schedules, and product specifications.

Cleaning and Basic Engine Service

Procedures for cleaning the generator and performing basic engine upkeep.

Fluid, Filter, and Spark Plug Service

Detailed steps for changing oil, filter, and replacing the spark plug.

Air System, Spark Arrestor, Storage, and Battery

Covers air cleaner, spark arrestor, storage, and battery replacement.

Warranty

Emission Control Warranty

Explains emission control system warranty rights, obligations, and coverage.

General Limited Warranty

Details the two-year limited warranty coverage for XG Series generators and its exclusions.

Generac Power Systems 005796-0 (XG6500) Specifications

General IconGeneral
BrandGenerac Power Systems
Model005796-0 (XG6500)
CategoryPortable Generator
LanguageEnglish