Generac
10000EXL
Extended
Life
Generator
GENERATOR
MAINTENANCE
Generator
maintenance
consists
of
keeping
the
unit
clean
and
dry.
Operate
and
store
the
unit
in
a
clean
dry
environment
where
it
will
not
be
exposed
to
excessive
dust,
dirt,
moisture
or
any
corrosive
vapors.
Make
sure
the
cooling
air
slots
in
the
generator
do
not
become
clogged
with
snow,
leaves
or
other
foreign
material.
Check
cleanliness
of
the
generator
frequently
and
clean
when
dust,
dirt,
oil,
moisture
or
other
foreign
substances
are
visible
on
its
exterior
surface.
NOTE:
We
DO
NOT
recommend
using
a
garden
hose
to
clean
generator.
Water
can
enter
the
engine
fuel
system
and
cause
problems.
In
addition,
if
water
enters
the
generator
through
the
cooling
air
slots,
some
water
will
be
retained
in
the
voids
and
cracks
of
the
rotor
and
stator
winding
insulation.
Water
and
dirt
buildup
on
the
generator
internal
windings
will
eventually
decrease
the
insulation
resistance
of
these
windings.
M
To
Clean
the
Generator
_
Use
a
damp
cloth
to
wipe
exterior
surfaces
clean.
Soft,
bristle
brush
may
be
used
to
loosen
caked
on
dirt
or
oil.
A
vacuum
cleaner
may
be
used
to
pick
up
loose
dirt
and
debris.
Low
pressure
air
(not
to
exceed
25
psi)
may
be
used
to
blow
away
dirt.
Inspect
cooling
air
slots
and
opening
on
generator.
These
openings
must
be
kept
clean
and
unobstructed.
STORAGE
INSTRUCTIONS
The
generator
should
be
started
at
least
once
every
seven
days
and
allowed
to
run
at
least
30
minutes.
If
this
cannot
be
done
and
you
must
store
the
unit
for
more
than
30
days,
use
the
following
guidelines
to
prepare
it
for
storage.
M
Generator
Storage
_
Clean
the
generator
as
outlined
in
“To
Clean
the
Generator.”
Check
that
the
cooling
air
slots
and
openings
on
the
generator
are
open
and
unobstructed.
Change
engine
oil.
Drain
fuel
and
run
engine
until
the
fuel
system
is
empty.
Remove
spark
plugs
and
pour
about
1
ounce
of
clean
engine
oil
into
spark
plug
holes.
Crank
engine
over
slowly
several
times,
to
distribute
oil.
Install
and
tighten
spark
plugs.
Extended
Store
the
unit
in
a
clean
dry
place.
DANGER:
Storage
covers
can
be
flammable.
Do
not
place
a
storage
cover
over
a
hot
generator.
Let
the
unit
cool
for
5
minutes
before
placing
cover
on
the
unit
M
Other
Storage
Tips
_
Do
not
store
gasoline
from
one
season
to
another.
Replace
your
gasoline
can
if
it
starts
to
rust.
Rust
and/or
dirt
in
a
gasoline
can
cause
problems
when
you
use
that
fuel
with
this
unit
Store
in
clean
and
dry
area.
SPECIFICATIONS
M
Generator
_
Rated
Maximum
Continuous
AC
Power
Output.J
0000
watts
(10
kW)
Rated
Voltage.120/240
Volts
Rated
Maximum
Current
at
240
Volts..41.7
AC
amperes
Rated
Maximum
Current
at
120
Volts.83.3
AC
amperes
Phase.1
Rated
AC
Frequency.60
Hertz
Number
of
Rotor
Poles.2
Driven
Speed
of
Rotor.3600
rpm
Battery
Size.Y50-N182-A3
Engine
Type.
.Air-Cooled
V-Twin
Displacement.
.570cc
Valve
Arrangement.
.Overhead
Valves
Setting
at
no
load.
.3600
rpm
Lubrication
System...
Oil
Capacity
With
Oil
Filter
Change.
.3.5
U.S.
Pints
Without
Oil
Filter
Change.
.3
U.S.
Pints
Recommended
Spark
Plugs
Champion.
.RC12YC
Autolite.
.3924
Spark
Plug
Gap.
.0.030
inch
(0.76mm)
Spark
Plug
Torque.
.200
inch-pounds
(22.5
N-m)
Rated
Horsepower.
.19
at
3600
RPM
Fuel
Canacitv.
....5
IJ.S.
Gallons
(19
Liters)
Generator
13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 10000EXL and is the answer not in the manual?

Generac Power Systems 10000EXL Specifications

General IconGeneral
BrandGenerac Power Systems
Model10000EXL
CategoryPortable Generator
LanguageEnglish

Related product manuals