EasyManuals Logo

Generac Power Systems 10000EXL User Manual

Generac Power Systems 10000EXL
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Generac
10000EXL
Extended
Life
Generator
TROUBLESHOOTING
POINTS
Problem
Cause
Correction
Engine
is
running,
but
no
AC
output
is
available.
1.
One
of
the
circuit
breakers
is
open.
2.
Fault
in
generator.
3.
Poor
connection
or
defective
cord
set.
4.
Connected
device
is
bad.
1.
Reset
circuit
breaker.
2.
Contact
Generac
Service
Facility.
3.
Check
and
repair.
4.
Connect
another
device
that
is
in
good
condition.
Engine
runs
good
at
no-load
but
“bogs
down"
when
loads
are
connected
1.
Short
circuit
in
a
connected
load.
2.
Engine
speed
is
too
slow.
3.
Generator
is
overloaded.
4.
Shorted
generator
circuit.
1.
Disconnect
shorted
electrical
load.
2.
Contact
Generac
Service
Facility.
3.
See
“Don't
Overload
the
Generator".
4.
Contact
Generac
Service
Facility.
Engine
will
not
start;
or
starts
and
runs
rough.
1.
Run/Stop
Switch
set
to
STOP.
2.
Dirty
air
cleaner
3.
Out
of
gasoline.
4.
Stale
gasoline.
5.
Spark
plug
wire
not
connected
to
spark
plug.
6.
Bad
spark
plug.
7.
Water
in
gasoline.
8.
Overchoking.
9.
Excessively
rich
fuel
mixture.
10.
Intake
valve
stuck
open
or
closed.
11.
Engine
compression
lost.
12.
Failed
battery.
1.
Set
switch
to
RUN.
2.
Clean
or
replace
air
cleaner.
3.
Fill
fuel
tank.
4.
Drain
gas
tank;
fill
with
fresh
fuel.
5.
Connect
wire
to
spark
plug.
6.
Replace
spark
plug.
7.
Drain
gas
tank;
fill
with
fresh
fuel.
8.
Open
choke
fully
and
crank
engine.
9.
Contact
Generac
Service
Facility.
10.
Contact
Generac
Service
Facility.
11.
Contact
Generac
Service
Facility.
12.
Replace
battery.
Engine
shuts
down
during
operation
1.
Out
of
gasoline.
2.
Low
oil
level.
1.
Fill
fuel
tank.
2.
Fill
crankcase
to
proper
level.
Engine
lacks
power.
1.
Load
is
too
high.
2.
Dirty
air
filter.
1.
See
“Don't
Overload
the
Generator”
2.
Replace
air
filter.
Engine
“hunts”
or
falters.
1.
Choke
is
opened
too
soon.
2.
Carburetor
is
running
too
rich
or
too
lean.
1.
Move
choke
to
halfway
position
until
engine
runs
smoothly.
2.
Contact
Generac
Service
Facility.
Extended
Lite
Generator

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 10000EXL and is the answer not in the manual?

Generac Power Systems 10000EXL Specifications

General IconGeneral
BrandGenerac Power Systems
Model10000EXL
CategoryPortable Generator
LanguageEnglish

Related product manuals