TROUBLESHOOTING
Problem
Pump has following
problems: failure to produce
pressure, erratic pressure,
chattering, loss of pressure,
low water volume.
Detergent fails to mix with
spray.
Engine runs good at no-load
but "bogs" when load is
added.
Engine will not start; or
starts and runs rough.
Engine shuts down during
operation.
Engine lacks power.
Engine "hunts" or falters.
Cause
I. Low pressure spray tip installed.
2. Water inlet isblocked.
3. Inadequatewater supply.
4. Inlet hose iskinked or leaking.
5. Clogged inlet hose strainer.
6. Water supply isover 100°F.
7. High pressure hose is blocked or
leaks.
8. Gun leaks.
9. Nozzle is obstructed.
10. Pump isfaulty.
I. Detergent siphoning tube is not
submerged.
2. Chemical filter is clogged or
cracked.
3. Dirty in-linefilter.
4. High pressure spray tip installed.
Engine speed is too slow.
I. Low oil level.
2. Dirty air cleaner.
3. Out of gasoline.
4. Stale gasoline.
5. Spark plug wire not connected to
spark plug.
6. Bad spark plug.
7. Water in gasoline.
8. Overchoking.
9. Excessively rich fuel mixture.
10. Intake valve stuck open or closed.
I I. Engine has lost compression.
Out of gasoline.
Dirty air filter.
Choke isopened too soon.
Correction
I. Replacespray tip with high pressure
spraytip.
2. Clear inlet.
3. Provide adequate water flow.
4. Straighten inlet hose, patch leak.
5. Check and clean inlet hose strainer.
6. Provide cooler water supply.
7. Clear blocks in outlet hose.
8. Replacegun.
9. Clean nozzle.
10. Contact Generac service facility.
I. Insert detergent siphoning tube into
detergent.
2. Clean or replace fitter/detergent
siphoningtube.
3. See"Check In-Line Filter" on page 13.
4. Replacespray tip with low pressure
spraytip.
Move throttle control to FASTposition. If
enginestill "bogs down", contact Briggsand
Stratton service facility.
I. Fill crankcase to proper level.
2. Clean or replace air cleaner.
3. Fill fuel tank.
4. Drain gas tank; fill with fresh fuel.
5. Connect wire to spark plug.
6. Replacespark plug.
7. Drain gastank; fill with fresh fuel.
8. Open choke fully andcrank engine.
9. Contact Briggsand Stratton service
facility.
10. Contact Briggsand Stratton service
facility.
I I. Contact Briggsand Stratton service
facility.
Fillfuel tank.
Replace air filter.
Move choke to halfway position until
engine runs smoothly.
/
15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 2700PSI 1676-0 and is the answer not in the manual?

Generac Power Systems 2700PSI 1676-0 Specifications

General IconGeneral
BrandGenerac Power Systems
Model2700PSI 1676-0
CategoryPressure Washer
LanguageEnglish

Related product manuals