Owner’s Manual
Questions? Help is just a moment away!
Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT
Web: www.generac-portables.com or www.briggsandstratton.com
Model No. 9777-4 (4,000 Watt AC Generator) Manual No. 193524GS Revision 0 (08/04/2003)
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-23
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Last Page
Generator
Wheel kit
Storage Cover
Battery charge cables
Spare Spark Plug,Air Filter, and Oil Filter
Spark Plug Wrench
Locking 20 Amp plug
Locking 30 Amp plug
Engine oil
Owner's manual
Engine manual
*If any parts are missing or damaged, call 1-800-270-1408.
Parts Included* Table of Contents

Other manuals for Generac Power Systems 4000XL

Questions and Answers

  • A
    Amy MullenAug 19, 2025
    What to do if my Generac Power Systems 4000XL runs good at no-load but bogs down when loads are connected?
    • A
      ashleykingAug 19, 2025
      If your Generac Power Systems Portable Generator runs well without any load but struggles when you connect devices, there could be a few reasons. First, a connected device might have a short circuit; try disconnecting electrical loads to resolve this. Second, the generator might be overloaded, so avoid overloading it. Finally, there could be a short circuit within the generator itself, in which case you should contact an authorized service facility.
  • E
    Edward ThompsonAug 21, 2025
    Why does my Generac Power Systems 4000XL shut down during operation?
    • J
      Jennifer ThomasAug 21, 2025
      Your Generac Power Systems Portable Generator might shut down during operation for a couple of reasons: 1. It might be out of gasoline. If this is the case, fill the fuel tank. 2. The oil level might be low. If this is the case, fill the crankcase to the proper level or place the generator on a level surface.
  • D
    dgarciaAug 25, 2025
    What to do if my Generac Power Systems 4000XL engine will not start?
    • C
      Colton LozanoAug 25, 2025
      If your Generac Power Systems Portable Generator engine won't start, there are several possible reasons: * The Run/Stop switch may be set to “Stop”. Set the switch to “Run.” * The air cleaner might be dirty. Clean or replace the air cleaner. * The generator could be out of gasoline. Fill the fuel tank. * The gasoline may be stale. Drain the gas tank and fill with fresh fuel. * The spark plug wire may not be connected to the spark plug. Connect the wire to the spark plug. * The spark plug could be bad. Replace the spark plug. * There might be water in the gasoline. Drain the gas tank and fill with fresh fuel. * The engine may be overchoking. Put the choke lever to the “No Choke” position. * The oil level could be low. Fill the crankcase to the proper level.
  • C
    cindyramirezAug 27, 2025
    Why does my Generac Power Systems 4000XL engine shut down during operation?
    • M
      mccoyandreaAug 27, 2025
      Your Generac Power Systems Portable Generator engine might shut down during operation because it is out of gasoline. In this case, fill the fuel tank. Another reason might be low oil level. Fill the crankcase to the proper level.
  • F
    fordkevinAug 28, 2025
    How to troubleshoot no AC output from my Generac Power Systems Portable Generator?
    • N
      Nancy HuberAug 28, 2025
      If your Generac Power Systems Portable Generator's engine is running but there's no AC output, here's what to check: * The circuit breaker may be open. Reset the circuit breaker. * There might be a poor connection or defective cord set. Check and repair it. * The connected device could be faulty. Connect another device that is in good condition.
  • B
    brownjonathanAug 30, 2025
    Why does my Generac Power Systems 4000XL Portable Generator engine lack power?
    • S
      Stephen DayAug 30, 2025
      Your Generac Power Systems Portable Generator engine may lack power if the load is too high. Another reason could be a dirty air filter. Replace the air filter.
  • A
    amanningSep 1, 2025
    What to do if my Generac Power Systems 4000XL Portable Generator engine runs good but bogs down when loads are connected?
    • I
      Isabel StarkSep 1, 2025
      If your Generac Power Systems Portable Generator engine runs well but bogs down when loads are connected, it could be due to a short circuit in a connected load. Disconnect the shorted electrical load. Also, the generator might be overloaded.
  • J
    Jesse WestSep 3, 2025
    Why does my Generac Power Systems 4000XL engine “hunt” or falter?
    • M
      Matthew WalkerSep 3, 2025
      Your Generac Power Systems Portable Generator engine might “hunt” or falter if the choke is opened too soon. Move the choke to the halfway position until the engine runs smoothly.
  • C
    Chad SuttonSep 6, 2025
    Why won't my Generac Power Systems Inverter engine start or runs rough?
    • D
      Donald CollinsSep 6, 2025
      If your Generac Power Systems Inverter engine won't start or runs rough, possible causes include: * The run/stop switch is set to “Stop”: set the switch to “Run”. * A dirty air cleaner: clean or replace it. * The unit is out of gasoline: fill the fuel tank. * Stale gasoline: drain the tank and fill with fresh fuel. * The spark plug wire isn't connected: connect it to the spark plug. * A bad spark plug: replace it. * Water in the gasoline: drain the tank and fill with fresh fuel. * Overchoking: put the choke lever to the “Run” position. * Low oil level: fill the crankcase to the proper level. For excessively rich fuel mixture, a stuck intake valve, or lost engine compression, contact a Generac Power Systems service facility.
  • J
    Jennifer ParkerSep 7, 2025
    What to do if my Generac Power Systems Inverter engine shuts down during operation?
    • K
      Kelli SmithSep 7, 2025
      If your Generac Power Systems Inverter engine shuts down during operation, it could be due to the following: * The unit is out of gasoline. Refill the fuel tank. * The oil level is low. Fill the crankcase to the proper level. If these steps don't resolve the issue, there may be a fault in the engine, and you should contact a Generac Power Systems service facility.

Summary

Safety Rules

Assembly

Before Starting Engine

Add Engine Oil and Fuel

Essential steps for adding the correct oil and fuel before initial engine startup.

Operating the Generator

Starting the Engine

Step-by-step guide for safely starting the generator engine.

Connecting Electrical Loads

Stopping the Engine

Charging a Battery

Receptacles

120;240 Volt AC, 20 Amp Locking Receptacle

Information on the 20 Amp locking receptacle and its power capabilities.

120 Volt AC, 30 Amp Locking Receptacle

Details on the 30 Amp locking receptacle and its power output.

Dont Overload Your Generator

Capacity

Guidance on calculating the generator's capacity and matching loads to its output.

Power Management

Strategies for sequentially adding loads to protect the generator and connected devices.

General Maintenance Recommendations

Troubleshooting

Limited Warranty

Generac Power Systems 4000XL Specifications