Generac Portable Products 5500XL Generator
GENERAL MAINTENANCE
RECOMMENDATIONS
The owner/operator is responsible for making sure that all
periodic maintenancetasks are completed on a timely
basis;that all discrepanciesare corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine Maintenance
Seeengine manualfor instructions.
Generator Maintenance
Generator maintenanceconsists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leavesor anyother foreign material.
NOTE: Do Not use a garden hose to cleangenerator.
Water canenter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation.Water
and dirt buildup on the generator windings wilt eventually
decrease the insulationresistance of these windings.
To Clean the Generator
Use a damp cloth to wipe exterior surfacesclean.
A soft bristle brush may be used to loosen caked on dirt
or oil.
A vacuum cleaner may be used to pick up loose dirt and
debris.
Low pressure air (not to exceed 25 psi) may be used to
blow awaydirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
STORAGE
The generator should be started at least once every seven
daysand allowed to run at least30 minutes. If this cannot
be done and you must store the unit for more than 30
days,usethe following guidelines to prepare it for storage.
Generator Storage
Clean the generator as outlined in "To Clean the
Generator."
Check that cooling air slots and openings on generator
are open and unobstructed.
_ DANGER! Storagecovers can be flammable. Do
Not placea storage cover over a hot generator. Let
the unit coot for a sufficient time before placingthe
cover on the unit
Engine Storage
See engine owner's manual for instructions.
Other Storage Tips
Do Not store gasoline from one season to another.
Replace your gasoline can if it starts to rust. Rust and/or
dirt in a gasoline can cause problems when you use that
fuel with this unit.
Store in clean and dry area.
SPECIFICATIONS
Maximum SurgeWatts ................. 6,875 watts
Continuous Wattage Capacity ........... 5,500 watts
Power Factor .............................. 1.0
Rated Maximum Continuous Load Current
At 120Volts ....................... 45.8 Amps
At 240 Volts ....................... 22.9 Amps
Phase ................................. I-phase
Rated Frequency ....................... 60 Hertz
FuelTank Capacity .................. 7 U.S.gallons
/
12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 5500XL and is the answer not in the manual?

Generac Power Systems 5500XL Specifications

General IconGeneral
BrandGenerac Power Systems
Model5500XL
CategoryPortable Generator
LanguageEnglish

Related product manuals