28
4.12 SERVICE SCHEDULE
ATTENTION: It is recommended that all service work
be performed by the nearest Dealer.
SYSTEM/COMPONENT PROCEDURE FREQUENCY
X = Action
R = Replace as Necessary
* = Notify Dealer if Repair is
Needed.
Inspect Change Clean
W = Weekly
M = Monthly
Y = Yearly
FUEL
Fuel lines and connections*
XM
LUBRICATION
Oil level
X M or 24 hours of
continuous operation.
Oil
X 2Y or 200 hours
of operation.**
Oil filter
X 2Y or 200 hours
of operation.**
COOLING
Enclosure louvers
XXW
BATTERY
Remove corrosion, ensure
dryness
XXM
Clean and tighten battery
terminals
XXM
Check charge state
X R EVERY 6 M
Electrolyte level
X R EVERY 6 M
ENGINE AND MOUNTING
Air cleaner
X R 2Y or 200 hours
Spark plug(s)
X R 2Y or 200 hours
GENERAL CONDITION
Vibration, Noise, Leakage, Temperature*
XM
COMPLETE TUNE-UP* TO BE COMPLETED BY A DEALER 2Y or 200 hours
* Contact the nearest dealer for assistance if necessary.
** Change oil and filter after first eight (8) hours of operation and then every 200 hours thereafter, or 2 years, whichever occurs first. Change
sooner when operating under a heavy load or in a dusty or dirty environment or in high ambient temperatures.
Maintenance