RECONNEaiON
FOR
DUAL
VOLTAGE
You
can
reconnect
the
generators
to
supply
a
dual
voltage
AC
output,
if
desired.
That
is,
units
may
be
reconnected
to
operate
120
and/or
240
volts,
1-
phase,
60
Hertz,
AC
loads.
This
is
done
by
connect¬
ing
the
hwo
stator
AC
power
windings
in
series
as
it
is
shown
in
Figure
2.
IMPORTANT:
UNITS
RECONNECTED
FOR
120/240
VOLTS
DUAL
VOLTAGE
OUTPUT
WILL
NOT
BE
LISTED
PER
RVIA.
NOTE:
The
Q-40G
can
NOT
be
reconnected
for
a
dual
voltage
output
of
120/240
volts
AC.
Figure
2
Reconnection
for
Dual
Voltage
Output
When
reconnecting
for
dual
voltage
output,
the
installer
should
replace
the
main
circiut
breakers
(CB1
and
CB2)
with
a
single
adequately
rated
circuit
breaker.
Rated
maximum
continuous
load
currents
are
listed
below:
NP-50LP
—18.8
AC
amperes
NP-50G
20.8
AC
amperes
Q-55G/LP
22.9
AC
amperes
NP-66G/LP
27.5
AC
amperes
Q-70G/LP
29.1
AC
amperes
NOTE:
This
option
is
unavailabe
on
the
Q40
model.
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems NP Series and is the answer not in the manual?

Generac Power Systems NP Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelNP Series
CategoryPortable Generator
LanguageEnglish

Related product manuals