RECONNEaiON
FOR
DUAL
VOLTAGE
You
can
reconnect
the
generators
to
supply
a
dual
voltage
AC
output,
if
desired.
That
is,
units
may
be
reconnected
to
operate
120
and/or
240
volts,
1-
phase,
60
Hertz,
AC
loads.
This
is
done
by
connect¬
ing
the
hwo
stator
AC
power
windings
in
series
as
it
is
shown
in
Figure
2.
IMPORTANT:
UNITS
RECONNECTED
FOR
120/240
VOLTS
DUAL
VOLTAGE
OUTPUT
WILL
NOT
BE
LISTED
PER
RVIA.
NOTE:
The
Q-40G
can
NOT
be
reconnected
for
a
dual
voltage
output
of
120/240
volts
AC.
Figure
2
Reconnection
for
Dual
Voltage
Output
When
reconnecting
for
dual
voltage
output,
the
installer
should
replace
the
main
circiut
breakers
(CB1
and
CB2)
with
a
single
adequately
rated
circuit
breaker.
Rated
maximum
continuous
load
currents
are
listed
below:
NP-50LP
—18.8
AC
amperes
NP-50G
20.8
AC
amperes
Q-55G/LP
22.9
AC
amperes
NP-66G/LP
27.5
AC
amperes
Q-70G/LP
29.1
AC
amperes
NOTE:
This
option
is
unavailabe
on
the
Q40
model.