EasyManuals Logo

Generac Power Systems NP Series User Manual

Generac Power Systems NP Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
SPECIFICATIONS
GENERATOR
SPECIFICATIONS
SERIES
Q-40G
NP-50G
NP-50LP
Q-55G/LP
NP-66G/LP
Q-70GA.P
Rotor
RPM
3600
3600
3600
3600
3600
3600
Rotor
Poles
2
2
2
2
2
2
Engine
RPM
2570
2570
2570
2570
2700
2570
Wattage*
4200
5000
4500
5500
6600
7000
Voltage*
120
120
120
120
120
120
Rated
Amps*
35
41.6V
37.5*
45.8*
.55*
58.3A
Phase
1
1
1
1
1
1
Frequency
60
60
60
60
Hertz
60
Hertz
60
Hertz
Weight
215
lbs.
207
lbs.
207lbs.
215
lbs.
213
lbs.
222
lbs.
Length
25
inches
Width
18.5
inches
Height
16.68
inches
All
units,
except
Q-40G,
are
reconnectable
to
120/240
volts,
dual
voltage
output.
When
reconnect¬
ed
for
dual
voltage,
units
are
not
listed
per
RVIA.
V
Rated
maximum
continuous
current
at
240
volts
is
20.8
amps.
t
Rated
maximum
continuous
current
at
240
volts
is
22.9
amps.
t
Rated
maximum
continuous
current
at
240
volts
is
27.5
amps.
A
Rated
maximum
continuous
current
at
240
volts
is
29.1
amps.
*
Rated
maximum
continuous
current
at
240
volts
is
18.8
amps.
ENGINE
SPECIFICATIONS
Type
of
Engine
NP-50G/LP.1
Cylinder,
4
Cycle
OHVI
NP-66G/LP,
Q-70G/LP
Q-40G,
Q-55G/LP.V-Twin,
4
Cycle
OHVI
Number
of
Cylinders
Q-40G,
Q-55G/LP,
NP-66G/LP,
Q-70G/LP.2
NP-50G/LP
.1
Valve
Configuration.Overhead
Valves
Cooling
Method
.Air-Cooled
Rated
Horsepower
NP-50G/LP
.
1
3
at
3600
RPM
Q-40G.16
at
3600
RPM
Q-55G/LP
.16
at
3600
RPM
NP-66G/LP
.16
at
3600
RPM
Q-70G/LP
.19
at
3600
RPM
Displacement
NP-50G/LP
.363cc
Q-40G
.480cc
Q-55G/LP.480CC
NP-66G/LP
.480CC
Q-70G/LP.570CC
Compression
Ratio.8.6
tol
Cylinder
Block.Aluminum
with
cast
iron
sleeve
Type
of
Governor.Mechanical,
fixed
speed
Air
Cleaner.Paper
element
with
foam
pre-cleaner
Starter.12
volts
DC
electric
Recommended
Spark
Plugs.Champion
RC12YC
Spark
Plug
Gap.0.030
inch
(0.8mm)
Oil
Filter
..Generac
Part
No.
70185
Crankcase
Oil
Capacity
.1.5
U.S.
quarts
Battery
Voltage.12
volts
DC
Recommended
Battery§
Amp-Hour
Rating
.70
amp-hour
Cold
Cranking
Amperes
.360.
Cranking
Current...100
DC
amperes
Battery
Ground..Negative
(-)
§
If
ambient
temperature
is
usually
below
32“F
(O^C),
use
a
battery
rated
at
95
amp-hours
and
450
cold¬
cranking
amperes.
RECOMMENDED
FUEL
For
the
gasoline-powered
units:
Use
clean,
fresh
UNLEADED
gasoline
with
a
minimum
octane
rating
of
87.
Leaded
REGULAR
grade
gasoline
is
an
accept¬
able
substitute.
FOR
GASEOUS
FUEL-POWERED
UNITS
Use
clean,
fresh
commercial
propane
gas.
The
optional
LP
gas
system
was
designed
for
a
VAPOR
WITHDRAWAL
type
system.
FUEL
CONSUMPTION
Gasoline
fuel
system
In
U.S.
gallons
per
hour:
%
'
OF
WATTS
1
SERIES
1
NP-50G
Q-40G
Q-55G
NP-66G
Q-70G
25%
0.16
0.16
0.21
0.25
0.27
50^S^
0.32
0.32
0.42
0.50
0.54
75%
0.46
0.47
0.62
0.74
0.81
100%
0.63
0.63
0.83
0.99
1.08
RECOMMENDED
ENGINE
OIL
Use
oil
classified
“For
Service
SP
and
having
an
SAE
viscosity
rating
of
10W-30.
Engine
crankcase
oil
capacity
is
1.5
U.S.
quarts
(1.6
liters).
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems NP Series and is the answer not in the manual?

Generac Power Systems NP Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelNP Series
CategoryPortable Generator
LanguageEnglish

Related product manuals