USING THE GENERATOR
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to theAC neutral wire (the neutral is bonded to the
generator frame).
Special Requirements
There may be Federalor State Occupational Safetyand
Health Administration (OSHA) regulations,localcodes,or
ordinances that apply to the intended use of the generator.
Pleaseconsult a qualified electrician, electrical inspector,or
the localagencyhavingjurisdiction.
In some areas,generators are required to be registered
with local utilitycompanies.
If the generator is used at a construction site, there may
be additional regulations which must be observed.
Connecting to a Building's Electrical
System
Connections for standby power to a buitding's electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable lawsand
electrical codes.
DANGER
When usinggenerator for backup power, notifyutility
company.Use approved transfer equipment to isolate
generator from electric utility.
Use aground fault circuit interrupter (GFCI) in anydamp or
highly conductive area,such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain.
DO NOT handle generator or electrical cords while standing
inwater, while barefoot, or while handsor feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
OPERATING THE
G EN ERATO R
CAUTION
See"Don't Overload Generator" on page I I.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Starting the Engine
Disconnect altelectrical loadsfrom the generator. Use the
following start instruction steps by numerical order:
I. Make sure unit is on a levelsurface.
IMPORTANT: Failure to start and operate unit on a level
surface will causethe unit not to start or shut down during
operation.
2. Turn the fuel valve to the "On" position (Figure 3).
Fuel Valve is shown
in the On position
3. Follow start instructions given in engine owner's
manual.
NOTE: If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection device.
See engine manual.
Connecting Electrical Loads
Let engine stabilize and warm upfor a few minutes after
starting.
Plug in and turn on desired 120 and/or 240VottAC,
singlephase,60 Hz electrical loads.
/
8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems PowerBOSS 8000 PowerMaster and is the answer not in the manual?

Generac Power Systems PowerBOSS 8000 PowerMaster Specifications

General IconGeneral
BrandGenerac Power Systems
ModelPowerBOSS 8000 PowerMaster
CategoryPortable Generator
LanguageEnglish

Related product manuals