Screen Indicators
OPERATING PRINCIPLES
HT300 room thermostat specifications:
LCD with backlight
Two-position control (ON / OFF)
Temperature sensor (NTC)
The thermostat measures the room temperature with its temperature sensor. The desired temperature value is set
by turning the button to the right or left. Relay opens when room temperature rises above set temperature and the
boiler will stop working.
Digital display; The set temperature, battery life, room temperature and heating symbol are displayed. The heating
o
symbol gives information about the operation status of the boiler. The product measures 0.1 C temperature
o
accuracy. However, there is an operating sensitivity of 0.5 C to prevent the heating unit from starting and stopping
too frequently.
The device manages the heating systems by the on-off operation algorithm. This working algorithm is shown in
the following graph.
generallife.com.tr3 / 9
Time
Heating System
OFF
Heating System
On
Desired
Temperature
Room
Temperature
1.
2.
3.
4.
5.
6.
7.
Set Temperature
Weekly Program Mode
Comfort Mode
Economy Mode
Holiday Mode
Manual Mode
Day Indicator
Hour Indicator
Battery Indicator
Boiler Operates
Screen Lock
Room Temperature
Hours of Day
8.
9.
10.
11.
12.
13.
C
O
C
C
O
C
1
2
3
4
5
6
7
9
10
11
8
13
12