4.4 Common causes of short burn time readings
Spark plug worn or gap too wide.
Spark plug connector damaged, loose or disconnected.
Excessive resistance in the ignition coil primary circuit.
Lean mixture.
4.5 Common causes of low spark KVolt readings
Shorted, dirty or too small spark plug gap.
Dirty or damaged spark plug insulator boot allowing spark tracking across
insulator.
Broken core in spark plug wire. Break is located between the distributor (or DIS coil)
and the test point.
Short circuit, disconnection or partial disconnection between the distributor (or DIS
coil) and spark plug wire.
Rich mixture. Most likely due to leaking fuel injector, or faulty oxygen sensor.
Low cylinder compression pressure. Could be caused by leaking valves, worn piston
rings, blown cylinder head gasket, etc.
4.6 Common causes of high spark KVolt readings
Spark plug worn or gap too wide.
Spark plug connector damaged, loose or disconnected.
Broken core in spark plug wire. Break is located be tween the spark plug and the
test point.
Lean mixture.