EasyManua.ls Logo

GENERGY MASELLA - Battery Connection for Electrical Startup

GENERGY MASELLA
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
English
WARNING: The charging battery acid is an aggressive and corrosive liquid,
use protective gloves and goggles before beginning battery preparation.
WARNING: Keep children and animals away from the area while performing
this operation, their actions can be unpredictable.
CAUTION: Do not mix the acid with other liquids or different acids, do not use
an acid other than the one supplied with your machine.
1 Remove the battery protection sticker.
2 Remove the plastic cap from the acid containers. Keep them. You will need
them later.
CAUTION: Do not puncture or
remove the safety seals from the
acid containers.
3 Press the acid containers against the battery so the seals are punctured by the
intended orifices.
4 Tap the acid containers softly so the acid is poured faster.
5 Use the plastic caps we kept in item "2" to close de battery definitively.
6 Install the battery by inverting the removal steps on the generator riser and fix
it to fastening rods.
7 Connect the generator supply wires on the battery terminals.
NOTE: Respect the cable polarities, connect the red cable (+) to the red
terminal
(+) of the battery and the black cable (-) to the negative (-) of the battery.
NOTE: Extreme precautions so as to not make unwanted contact with the
battery terminals and cables, among them or against a metallic part of the
machine.