4. Pre-Installation Checklist
IMPORTANT NOTICE
Read through the instructions thoroughly and obtain all materials and tools before proceeding with the
installation. Be sure to follow all applicable national, state, county and local plumbing codes and regulations.
All plumbing and electrical work should be performed by an accredited professional to ensure all local,
state, and municipal guidelines 
are met.
During cold weather it is recommended that the installer warm the valve to room temperature before
operating.
For outdoor installation ensure that system cannot freeze and is protected from direct sunlight and weather
conditions including rain. Outdoor weather cover can be added for additional weather protection of the
control valve. Warranty coverage does not include damage due to weather or acts of God.
Required Operating Conditions 
CAUTION 
Do not exceed 120 psi water pressure. 
Do not exceed 35° C / 125° F water temperature. 
Do not subject unit to freezing conditions. 
Failure to use this product within the described conditions may void the warranty. 
Working Conditions 
Working Pressure 
20psi  88psi 
Water Temperature 
35 °F  125 °F 
Working Environment 
Environment Temperature 
35 °F  125 °F 
Relative Humidity  ≤95% 
Power Source  100-240VAC / 50-60Hz
Inlet Water Quality 
Turbidity 
5 FTU
~
~
~
 
Hardness 
20 grains per gallon 
Chlorine 
0.1ppm 
Iron
2+
 
<
<
<
0.3ppm 
Genesis 
2 Iron Pro Max Water Softener and Iron Filtration System Manual