Storage Temperature | -40°C to +70°C |
---|---|
Rated Current | 16A |
Dielectric Strength | 2kV |
Humidity | 95% RH |
Terminal Type | Screw type |
Mounting Type | DIN rail |
Disassemble the interlock, place the bottom plate, and follow the main breaker cutout.
Turn off the main breaker and remove the panel cover.
Drill holes as marked on the panel cover with the provided drill bit and remove burs.
Install screws, bottom plate, top plate, retaining nuts, and thread lock for proper movement.
Install the 2-pole generator breaker and place the Generator Warning Sticker.
Use zip ties to secure breakers, tighten, trim, and install the warning label.
Re-install panel cover and verify proper interlock operation for both breaker states.
Place generator start-up procedure and caution labels on the panel box and meter pan.