Logic “AP” Step-by-step automatic C=from 1 to 7 d=1 E=0
Automated
system status
Inputs
Open/Close Open Close Stop
Safety devices
y=0
Closing safety devices
y=1
Opening and closing
safety devices
Closed
Opens and re-closes after
pause time
Opens and re-closes after
pause time
No effect
No effect (if active, it disa-
bles all commands)
No effect
Disables Open comman-
ds
Open in
pause
P=0 Closes immediately P=0 No effect
P=0 Closes immediately P=0 Stops operation
P=0, o=0 On release, re-clo-
ses after 5 secon-
ds, after pause
time.
P=0 On release, re-closes
after 5 seconds, after
pause time.
P=1 Recharges pause time,
if held down stops ope-
ration of the automa-
ted system, on release
re-closes after pause
time
P=1 Recharges pause time,
if held down stops ope-
ration of the automa-
ted system, on release
re-closes when pause
time has elapsed.
P=1 On release, re-closes
after 5 seconds when
pause time has elap-
sed. When the safety
device is engaged,
if it receives a CLOSE
or OP/CL command,
it memory-stores the
command and rechar-
ges pause time.
P=1, o=0 On release, re-clo-
ses after 5 secon-
ds when pause
time has elapsed.
When the safety
device is enga-
ged, if it receives
a CLOSE or OP/CL
command, it me-
mory-stores the
command and
recharges pause
time.
P=1 Recharges pause time,
if held down stops ope-
ration of the automa-
ted system, on release
re-closes when pause
time has elapsed.
P=1 Stops operation
P=0, o=1 Re-closes imme-
diately on release
P=1, o=1 Re-closes imme-
diately on release
At closure
Stops operation, opens on
next pulse.
Reverses movement to
opening
No effect Stops operation
Reverses movement to
opening
Stops operation and rever-
ses on release
At opening
Stops operation, closes on
next pulse
No effect
Reverses movement to
closure
Stops operation No effect
Stops operation and resu-
mes on release