Intraoral Imaging System
GIX-1
For Veterinary Only
User Manual
UM-603 CE VET
2022.12.09 Document Ver. 1.4
Copyright 2012 by GENORAY Co., Ltd. All Rights Reserved
Question and Answer IconNeed help?

Do you have a question about the GENORAY GIX-1 and is the answer not in the manual?

Summary

Preface

Copyright

Overview

Overview of the Manual

Explains manual structure, notations, warnings, symbols, and contents.

Overview of the Product

Describes the product, its intended use, user classification, labels, and information security.

Safety Precautions

General Safety Precautions

General safety guidelines and risk factors to consider during use.

Radiation Safety Precautions

Guidelines for radiation safety and protection during operation.

Precautions Before Using

Important checks and considerations before operating the device.

Precautions When Using

Specific precautions and best practices during product operation.

Instructions for Cleaning

Detailed instructions for cleaning and disinfecting the intraoral sensor.

Maintenance

Guidelines for visual inspection and regular maintenance of the product.

Instructions for Storage

Procedures for safely storing the intraoral sensor and its components.

Cases of Breakage due to Users Negligence

Identifies damage from user negligence, including cover, cable, and connector issues.

Image Acquisition

Image Acquisition Method

Step-by-step guide on how to acquire images using the device.

Troubleshooting

Solutions for Failed Image Acquisition

Countermeasures for issues where image acquisition fails.

Failure of Image Acquisition Without X-ray Exposure

Addresses image acquisition failures occurring without X-ray exposure.

Measure ADC Offset and Set Threshold

Procedure to measure ADC offset and set thresholds when X-ray is off.

Image Acquisition Failure After Raising ADC Offset

Troubleshooting image acquisition failures after adjusting ADC offset.

Specifications

Intraoral Sensor Specifications

Detailed technical specifications of the intraoral sensors.

Intraoral Sensor Usage Environment

Recommended environmental conditions for optimal operation and storage.

Waste Treatment Method

Dose Information

Calibration

Port-X II Calibration

Instructions for calibrating the Port-X II device.

Port-X III Calibration

Instructions for calibrating the Port-X III device.

Port-X IV Calibration

Calibration instructions for Port-X IV, IVe, ZEN-PX4, ZEN-PX4e.

Other Portable Equipment Calibration

Guidance for calibrating other compatible portable equipment.

GENORAY GIX-1 Specifications

General IconGeneral
TypeDigital Radiography System
ApplicationGeneral Radiography
Image Matrix3072 x 3072
Dynamic Range16-bit
Focal Spot Size0.6 / 1.2 mm
Anode Heat Capacity300 kHU
WorkstationIncluded
Detector Size17" x 17"
X-ray Tube Voltage40 - 150 kVp
Generator TypeHigh Frequency